Panels:  the Thin Seam panel shall have a 1¾" seam height, a maximum seam width of ", and a seam spacing of 12", 14", 16", or 18" wide. Roof panels shall use a two-piece roof clip allowing for thermal movement of the panel system. The standing seam shall have a built in capillary break with the option of a factory applied sealant in the female leg.  Concealed one piece roof clip will engage the panel seal allowing for unlimited thermal movement.  The standing seam shall snap lock together without the use of or need for an electric seaming device.  Roof panels shall be removable for replacement of damaged materials during and after installation is completed. The panel system shall be as a true standing seam shape requiring no trapezoidal foam closures, plugs, or fillers at eaves.

Specifications


  • Standard widths available: 16" and 18"
  • Multiple UL90 ratings
  • Minimum roof slope: 1:12
  • Factory applied sealant is standard
  • Stiffening ribs or shadow lines available for different aesthetic requirements
  • Can be installed over open framing or solid substrates


 
Amp Lok Metal Roofing PDF Print

Image

Description

Amp Lok structural standing seam roof system as manufactured by Fabral, 3449 Hempland Road, Lancaster, PA 17601, ph.:  800-477-2741; fax:  800-283-4289.
The Amp Lok panel shall have a coverage of 12", 14", 16", or 18".  Seams shall be 2" high. Roof panels shall use a two-piece roof clip allowing for thermal movement of the panel system. The panel shall have a factory-applied mastic and be mechanically seamed with a field operated electric seaming machine provided by the manufacturer. The panel system shall be as a true standing seam shape requiring no trapezoidal foam closures, plugs, or fillers at eaves.  Panels have 1" shadowlines as a standard. 

Specifications


  • Factory applied sealant is standard
  • Mechanical seaming ensures weather-tightness
  • 2 piece clip allows for thermal movement
  • Standard widths: 16" and 18"
  • Minimum roof slope: 1:12
  • Shadow lines are standard
  • Multiple UL90 ratings
  • Can be factory or field curved - minimum 10 foot radius
  • Panels can be tapered
  • Can be installed over open framing or solid substrate
  • Allowable loads are based on 1980 edition of AISI specifications.
  • Deflection is limited to L/240 of span.
  • Loads are based on spans of 3 or more.
  • FY=50 ksi for steel panels.
  • Uplift values based on attachment to 16 ga purlins with 2 # 10-16x1" SD ST screws.


 

 
Double Lok Metal Roofing PDF Print

Image

Description

 

Panels:  the Double Lock panel shall be formed as 1½" seam height with a seam spacing of 12", 16", or 20" on center. Roof panels shall use a two-piece roof clip allowing for thermal movement of the panel system. The panel shall be mechanically seamed with a field-operated, electric- seaming machine provided by the manufacturer. The panel system shall be as a true standing seam shape requiring no trapezoidal foam closures, plugs, or fillers at eaves. The maximum panel length shall be 40' (consult with factory for longer lengths). his panel shall be installed over a solid deck only. 

Specifications

 

  • Designed for commercial and residential applications
  • Panels can be tapered
  • An economical mechanically seamed roof panel
  • 2-piece clip allows for unlimited thermal movement
  • Provides a traditional 5-ply double lock standing-seam
  • Requires installation over solid substrate
  • Minimum roof slope: 3:12
  • 4 widths available: 12", 16", 18" and 20"

  {/tabs)

 
Grand Curve Metal Roofing PDF Print

Image

Image

Description


Engineered for durability and flexibility, Grand Curve handles the gentle slopes and changing lines of twenty-first century buildings with ease. Plus two different cap options provide two distinctly different appearances for maximum curb appeal.

Specifications


  • Available in G90 Steel, Galvalume with acrylic coating, Aluminum or Copper substrates
  • Panels can be curved to a 15' minimum radius
  • UL 90 rated on narrow cap system
  • 1 3/4" or 2" depth
  • Optional wide batten or narrow cap design
  • Curved battens/caps to exact dimensions
  • Clips provide unlimited thermal movement
  • ASTM E1592 test reports for both wide and narrow batten systems
  • Custom panel widths & coverage options available, please inquire


 

 
Slim Seam Metal Roofing PDF Print

Image

Description


The Slim Seam panel shall have a coverage of 12" or 16".  Seams shall be 1½" high. Roof panels shall use a one-piece roof clip allowing for unlimited thermal movement of the panel system. The panel shall have a factory applied mastic and be seamed by snapping together the integral seam. The panel system shall be as a true standing seam shape requiring no trapezoidal foam closures, plugs, or fillers at eaves.

Specifications

  • An economical, high-performing standing-seam roof system that's ideal for architectural, commercial and residential applications
  • Panels can be tapered
  • Unique stainless steel clip allows unrestricted thermal movement
  • Installer friendly—snap-together side joint requires no mechanical seaming
  • Factory formed panels, with factory-applied sealant
  • Multiple UL ratings for both steel and aluminum substrates
  • UL Class A fire rated
  • Usually installed over solid substrate but may be installed over open framing with 3' O.C. maximum spacing
  • Minimum roof slope: 1:12
  • Available widths: 12" and 16"

 
High Seam Metal Roofing PDF Print
Image

Description


Panels:  the High Seam panel shall have a 1½" seam height with a maximum seam width of ¼" and a panel coverage of 12", 14", 16", 18", or 20". Roof panels shall use a one-piece roof clip allowing for thermal movement of the panel system. The panel shall snap lock together without the use or need of an electric seaming machine.  Roof panels shall be removable for replacement of damaged materials during and after installation is completed. The panel system shall be as a true standing seam shape requiring no trapezoidal foam closures, plugs, or fillers at eaves. Panels are available smooth or with 1" shadowlines.

Specifications


  • Panel seams snap together—no mechanical seaming required
  • Panels can be tapered
  • One-piece clip allows unlimited thermal movement
  • UL90 rating for installation over plywood substrate
  • Optional shadow lines available
  • Installation over solid substrate is required
  • Minimum roof slope: 2:12
  • Standard widths: 16" and 18"


 
Snap-On-Batten Metal Roofing PDF Print
Image

Description


The Snap-on-Batten panel shall have a seam height of 1½" and spaced 12", 14", 16", 18", or 20" o.c.  The snap on batten cap will be 1½" wide by 1¾" tall. Roof panels shall use a one-piece roof clip allowing for thermal movement of the panel system.

Specifications


  • Classic bold box batten look
  • Concealed clip allows for thermal movement
  • Panels can be tapered
  • Requires solid substrate for installation
  • Minimum roof slope: 3:12
  • 4 widths available: 12", 16", 18" and 20"


 
Snap-On-Seam Metal Roofing PDF Print
Image

Description


The Snap-on-Seam panels shall have a seams that are 1¾" tall (also available in 1" seam height) and spaced 12", 14", 16", 18", or 20" o.c.  The panels are held in place with one-piece, concealed clips that permit thermal movement.  A narrow seam cap will then snap over the seam and clips. This panel may be curved with a minimum radius of 5'.  The panel seam leg will be shortened to enhance radius capabilities.

Specifications


  • Ideal for roof applications requiring curved panels
  • Concealed clip allows for thermal movement
  • 1" Panel can be curved to a minimum radius of 5' 0"
  • Panels can be tapered
  • Easily handles roof to fascia transitions
  • Installation over solid substrate is required
  • Minimum roof slope: 3:12
  • 4 widths available: 12", 16", 18" and 20"


 
Stand 'N Seam Metal Roofing PDF Print

Image

Description

A high-performance, structural standing-seam roof system for the most demanding applications. Test reports confirm that Stand 'N Seam has the highest wind uplift resistance of any standing-seam panel available in the market. Unique one-piece stainless steel clip design does not fold into side joint of panel, allowing unrestricted thermal movement

Specifications


  • Side joints are double lock-seamed with electric seaming machine ensuring weathertightness
  • Factory or field-formed by portable roll-former provides continuous long-length panels from ridge to eave and eliminates unsightly end-laps. Field forming available by qualified Fabral operators
  • Factory applied sealant is standard
  • ASTM E1592 and Multiple UL90 ratings in both steel and aluminum for applications over open framing or solid substrates
  • Fully tested performance for air and water infiltration
  • Multiple UL fire resistant assemblies available and Class A fire rated
  • Minimum roof slope: 1/2:12
  • Available widths: 12" and 16"


 
T-Rib Metal Roofing PDF Print
Image

Description


Panels:  The T-Rib panel shall have a width of 12", 14", 16", or 18" wide.  Seams shall be 2½" high with a ½" top flange angled at 90 degrees from the seam to facilitate the seaming of the panel and cap.  The panels shall have 1/16" x 1" stiffening ribs in the pan of the panel. Roof panels shall use a one-piece roof clip allowing for thermal movement of the panel system. The panel shall have a factory applied mastic and be mechanically seamed with a field operated electric seaming machine provided by the manufacturer. The panel system shall be as a true standing seam shape requiring no trapezoidal foam closures, plugs, or fillers at eaves. The maximum cap length shall be 30'.

Specifications


  • A 21/2" high rib panel with excellent design flexibility
  • Ease of installation for difficult hip, ridge, and valley conditions
  • Mechanically seamed cap strip with factory- applied weatherstripping assures a weather-tight seam
  • One-piece concealed clip allows for unlimited thermal movement
  • Panels can be tapered
  • Symmetrical design allows panels to be installed in either direction
  • Multiple UL90 ratings for steel panels
  • Can be installed over open framing or solid substrate
  • Minimum roof slope: 1/2:12
  • Standard widths: 16" and 18"


 
Posi-Lock Soffit PDF Print

Image

  • .032 aluminum and 24 gauge steel are standard
  • Interlocking design with concealed fasteners allow for fast and economical installation
  • Available solid or vented (9.2% open area)
  • Standard lengths: 6'-45'

 

 
LP-15 Liner PDF Print

Image

  • Perfect for field-assembled projects requiring insulated walls and roofs
  • Panel legs allow for easy attachment of subgirts
  • Factory applied sealant in overlapping rib to ensure a weathertight assembly
  • Standard polyester paint finish
  • Available perforated for acoustical applications
  • Thermal and acoustical test reports available
  • Standard lengths: 6'-45'

 

 
Decor Flush Specifications PDF Print

Image

The Decor-Flush panels shall have one 12" wide raised rib for a total coverage of 12".  The 12" rib shall have a depth of 1".  At the buyer’s discretion, two minor stiffening ribs shall be centered in the flat of the panel to minimize potential oil-canning.  The panels shall have an interlocking sidelap feature which hides the fasteners.  Joints may be factory caulked to provide additional weathertightness. Panels shall be attached to the substrate with concealed fasteners 

  • Ideal for soffits, fascias and vertical wall applications
  • Concealed fasteners for maximum aesthetic value
  • Factory applied sealant at side joint
  • Pencil grooves available
  • Standard lengths: 6'-45'

 
CFP 6 / CFP 12 Metal Siding PDF Print

Image
Image

Description


The CFP 6 panels shall have one 6" wide raised rib and 6" wide flush rib for a total coverage of 12".  The raised rib shall have a depth of 1 7/16".  There shall be one small stiffening bead centered in each rib.  The panels shall have an interlocking sidelap feature which hides the fasteners. Panels shall be attached to the substrate with concealed fasteners.

Specifications


  • Concealed fasteners for maximum aesthetic value
  • 2 stiffening ribs standard
  • Perfect for walls, fascias and equipment screens
  • Panel ends can be swedged and endlapped
  • Available with factory-applied sealant to ensure a weathertight wall assembly
  • Standard lengths: 6'-45'




 
spacer.png, 0 kB